Home
Product Directory
Electrical & Electronics
Power Transmission & Transformer
Transformer
S9 Series Transformer
US$10,000.00 | 1 Piece (MOQ) |
Production Capacity:
10000sets/Month
Transport Package:
Wooden
Payment Terms:
L/C, T/T
Yueqing Champn Electric Co., Ltd.
Zhejiang, China
Last Login Date:
Sep 23, 2020
Main Products:
Switchgear, Transformer, Substation, Ring Main Unit, Power Transformer, Prefabricated Substation
Find Similar Products
Product Description
Company Info
Basic Info.
Application
Electronic
Phase
Three
Core
Core-type Transformer
Cooling Method
Oil-immersed Type Transformer
Winding Type
Two-winding Transformer
Trademark
CHP
Specification
AS PER SPECIFICATION
Origin
China
HS Code
8504210000
Product Description
Oil-Immersed Transformer can serve both indoors and outdoors at an ambient temperature up to 400C. With reasonable structure, they are capable to withstand short-circuit and overload, and they are free of maintenance and easy to repair.
Functional characteristics
Technical Parameters
Rated Capacity (kVA): 10~6300 kVA
Vecor Group: Yyn0 or Dyn11
Impedance Voltage (%): 4%, 4.5%(Or as customer requirement)
Rated voltage: H. V: 11, 10.5, 10, 6.3, 6KV (Or as customer requirement)
L. V.: 0.4 KV (Or as customer requirement)
Tapping range: +/- 5% or +/- 2 * 2.5% (Or as customer requirement)
Frequency: 50Hz
Number of phases: 3
Cooling method: ONAN or ONFN
Temperature rise limits: Winding ≤ 65K
Top oil ≤ 60K
Standards: GB1094 Power transformer
GB/T6451 Technical data & requirement of three-phase oil immersed power transformer
IEC60076 Power transformer
Service conditions
Normal service conditions:
1) Altitude: ≤ 1, 000m
2) Highest ambient temperature: +40
3) Highest annual average temperature: +20
4) Indoor and outdoor
5) Highest daily average temperature: +30
6) Lowest temperature: -25
7) We can also provide transformers operated in special conditions according to users'.
Functional characteristics
Technical Parameters
Rated Capacity (kVA): 10~6300 kVA
Vecor Group: Yyn0 or Dyn11
Impedance Voltage (%): 4%, 4.5%(Or as customer requirement)
Rated voltage: H. V: 11, 10.5, 10, 6.3, 6KV (Or as customer requirement)
L. V.: 0.4 KV (Or as customer requirement)
Tapping range: +/- 5% or +/- 2 * 2.5% (Or as customer requirement)
Frequency: 50Hz
Number of phases: 3
Cooling method: ONAN or ONFN
Temperature rise limits: Winding ≤ 65K
Top oil ≤ 60K
Standards: GB1094 Power transformer
GB/T6451 Technical data & requirement of three-phase oil immersed power transformer
IEC60076 Power transformer
Service conditions
Normal service conditions:
1) Altitude: ≤ 1, 000m
2) Highest ambient temperature: +40
3) Highest annual average temperature: +20
4) Indoor and outdoor
5) Highest daily average temperature: +30
6) Lowest temperature: -25
7) We can also provide transformers operated in special conditions according to users'.
Send your message to this supplier